NIK 2303

Three-phase meter

  • Disconnector 120 A
  • Measurement with accuracy class 0.5 S
  • Active and reactive energy
  • Instantaneous values ​​of power, voltage, amperage
  • 4 tariffs / 12 zones
  • 4 measuring elements (optional)
  • Prepaid functions (optional, together with the NOVASYS software package)
  • Optical port
  • Operation voltage range from 100...400 V for transformer connection
  • Protection against theft of electricity:
    indication of incorrect connections increased and decreased voltages
  • Sensors of influence of magnetic and electromagnetic fields
  • Tamper sensor for case and terminal cover
  • Transparent case
  • Battery mode, external power supply connection
  • Voltage quality control function

Основні характеристики

Meter type

Electronic, Electronic

Number of phases

Three-phase, Three-phase

Active / reactive energy:

AR, AR

Accuracy class of active energy measurement:

0,5 S, 0,5 S

Fraud protection

Electromagnetic field indication, Electromagnetic field indication, Indication of the magnetic field, Indication of the magnetic field, Mechanical intervention sensors, Mechanical intervention sensors

Interfaces

Optical port, Optical port, PLC, PLC, RF 2,4 Ghz, RF 2,4 Ghz, RS-485, RS-485

Tariffs

Tariff meter

Reserve power supply

Connecting an external power supply, Connecting an external power supply

Options

Indication of phases, Voltage quality control, Indication of incorrect connections, Indication of phases, Load disconnection relay, Voltage quality control, Indication of incorrect connections, Load disconnection relay

Design features

Optoport cover protection, Optoport cover protection, Transparent case, Transparent case

Quantity of measuring elements

4, 4

Prepayment function

With NovaSys software, With NovaSys software

Three-phase meter

Specifications

Accuracy class for measuring of active energy:
EN 62053-211
EN 62053-220,5 S (for transformer connection)
Accuracy class for measuring of reactive energy:
EN 62053-232
Nominal voltage3х220/380 V
3х230/400 V
3х240/416 V
3х57,7/100 V (for transformer connection)
3х57,7/100 V … 3×240/416 V
(Wide range, for transformer connection)
Operation voltage range -20 … +15%
Nominal frequency50 Hz
Nominal current5 А
Maximum current10 A; 80 A; 120 A
Meter constant8000 imp / (kW*h)
Starting current for measuring of active energy :
for meters of direct conection class 1,012,5 mА
for meters of transformer conection class 1.0 (0.5 S)10 mА
Starting current for measuring of reactive energy :
for meters of direct conection class 1,015,6 mА
for meters of transformer conection class 1.0 (0.5 S)15 mА
Power consumption, no more than
in the voltage circuits without PLC interface10 V•A (2 W)
in the voltage circuits with PLC interface20 V•A (5 W)
in current circuits0,05 V•A
Operating temperature-40 … +70 °C
Weight, no more1,3 kg
Number of digits on LCD6 + 2
Service life24 years

 

Dimensions

Table of construction types