NIK 2307

Three-phase meter

  • Two interfaces
  • Instant values of power, voltage, amperage
  • GPRS/LTE
  • Active and reactive energy
  • 4 tariffs / 12 zones
  • Modern communication interfaces
  • Additional interface
  • Optical port
  • Disconnector
  • Sensors of magnetic and electromagnetic fields
  • Tamper sensor for case and terminal cover
  • Transparent / not transparent case (optional - integral)
  • Battery mode (optional - two batteries),
    connecting an external power supply
  • Measurement with accuracy class 0.5 S
  • Voltage quality control
Meter type

Electronic, Electronic

Number of phases

Three-phase, Three-phase

Active / reactive energy:

AR, AR

Accuracy class of active energy measurement:

0,5 S, 0,5 S

Fraud protection

Electromagnetic field indication, Electromagnetic field indication, Indication of the magnetic field, Indication of the magnetic field, Mechanical intervention sensors, Mechanical intervention sensors

Interfaces

Ethernet, Ethernet, GSM, GSM, Optical port, Optical port, PLC, PLC, RF 2,4 Ghz, RF 2,4 Ghz, RS-485, RS-485

Tariffs

Tariff meter

Reserve power supply

2 batteries, 2 batteries, Connecting an external power supply, Connecting an external power supply

Prepayment function

There is prepayment function, There is prepayment function

Options

Voltage quality control, Indication of incorrect connections, Load disconnection relay, Voltage quality control, Indication of incorrect connections, Load disconnection relay

Design features

Split case, One-piece case, Non-transparent body, One-piece case, Non-transparent body, Optoport cover protection, Optoport cover protection, Transparent case, Transparent terminal cover, Split case, Transparent case, Transparent terminal cover

Quantity of measuring elements

3, 3

Three-phase meter

Specifications

Accuracy class for measuring of active energy:
EN 62053-211
EN 62053-220,5 S (for transformer connection)
Accuracy class for measuring of reactive energy:
EN 62053-232
Nominal voltage3х220/380 V
3х230/400 V
3х240/416 V
3х57,7/100 V (for transformer connection)
3х57,7/100 V … 3×240/416 V (wide range, for transformer connection)
Operation voltage range-20 … +15%
Nominal frequency50 Hz
Nominal current5 А
Maximum current10 A; 80 A; 120 A
Meter constant8000 imp / (kW*h)
Starting current for measuring of active energy :
for meters of direct conection class 1,012,5 mА
for meters of transformer conection class 1.0 (0.5 S)10 mА (5 mА)
Starting current for measuring of reactive energy :
for meters of direct conection class 1,015,6 mА
for meters of transformer conection class 1.0 (0.5 S)15,0 mА (9,3 mА)
Power consumption, no more:
in the voltage circuits without PLC interface10 V•A (2 W)
in the voltage circuits with PLC interface20 V•A (5 W)
in current circuits0,05 V•A
Operating temperature-40 … +70 °C
Protection levelІР 54
Weight, no more than2,3 kg
Number of digits on LCD6 + 2
Service life24 years

 

Dimensions